Function diagrams
Input/Output Terminals
2-508
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Fig. 2-13 2220 – CU240E-2: Digital inputs, electrically isolated (DI0 ... DI5)
- 2220 -
Function diagram
87654321
FP_2220_97_02.vsd
External Interfaces
G120 CU240E-2
13.12.2010 V4.4
Digital inputs, electrically isolated (DI0  DI5)
+24 V OUT
Kl.9
Kl.5
Kl.6
Kl.7
Kl.17
p0795.1
p0795.2
p0795.5
Kl.28
GND
24 V
5 V
<1>
1
0
1
0
1
0
1
0
1
1
1
1
DI5
DI2
DI1
DI0
r0721.0
r0721.1
r0721.2
r0721.5
p0796.5
p0796.2
p0796.1
p0796.0
Kl. = Terminal
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
Kl.8
p0795.3
1
0
1
DI3
r0721.3
p0796.3
Kl.16
p0795.4
1
0
1
DI4
r0721.4
p0796.4
CU DI simulation
p0795
1 = Simulation on
.0
.0
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
.1
.1
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
.2
.2
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
.3
.3
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
.4
.4
CU DI status inv
r0723
r0723
CU DI status
r0722
r0722
.5
.5
T0
T0
CU DI t_debounce
p0724
T0
T0
T0
T0
CU DI t_debounce
p0724
CU DI t_debounce
p0724
CU DI t_debounce
p0724
CU DI t_debounce
p0724
CU DI t_debounce
p0724
.0
External power supply
24 V DC
Kl.69
DI COM
PNP
Kl.9
Kl.5
Kl.6
Kl.7
Kl.17
Kl.28
GND
DI5
DI2
DI1
DI0
Kl.8
DI3
Kl.16
DI4
Kl.69
NPN
+24 V OUT
DI COM
Kl.5
Kl.6
Kl.7
Kl.17
DI5
DI2
DI1
DI0
Kl.8
DI3
Kl.16
DI4
Kl.69
DI COM
or
<1>
<1>
Sampling time of the DI : 2 ms
Kl.34
DI COM2
Kl.34
DI COM2
Kl.34
DI COM2

Table of Contents