List of Parameters
Parameters
1-77
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the speed actual value measured using the BERO.
Dependency: Refer to: p0580, p0583
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description: Displays the time between the last two BERO pulses.
The measuring time is specified as 32-bit value with a resolution of 1/48 µs.
If a new pulse is not received before the maximum measured time in p0583 expires, then r0587 is set to the maxi-
mum measuring time.
Dependency: Refer to: p0580
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
Description: Displays the number of measuring pulses that have occurred (been received) up until now.
Dependency: Refer to: p0580
Note: After reaching 4294967295 (2^32 - 1), the counter starts again at 0.
Description: Displays the time since the last measuring pulse was detected.
The delay time is specified as 32-bit value with a resolution of 1/48 µs.
When a measuring pulse occurs (is received) the delay time is reset and is limited to the maximum measuring time
in p0583.
Dependency: Refer to: p0580
Note: For p0580 = 0 (no measuring probe), a value of zero is displayed here.
r0586 CO: Measuring probe, speed actual value / MT n_act
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2000 Data set: -
Units group: 3_1 Unit selection: p0505
Min Max Factory setting
- [rpm] - [rpm] - [rpm]
r0587 CO: Measuring probe, measuring time measured / MT t_meas measured
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r0588 CO: Measuring probe, pulse counter / MT pulse counter
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r0589 Measuring probe, delay time / MT t_delay
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -