Free Function Blocks
Function diagrams
2-609
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Fig. 2-104 7212 – OR (OR function block with 4 inputs)
- 7212 -
Function diagram
87654321
FP_7212_97_51.vsd
Logic function blocks
G120 CU240B/E-2
13.12.2010 V4.4
OR (OR function block with 4 inputs)
OR 1
OR 0
OR 3
OR 2
I0
I1
I2
I3
Q
[0]
OR 0 inputs
p20046
[1]
[2]
[3]
OR 0 output Q
r20047
OR 0 RTG
1 ... 9999
p20048 (9999)
OR 0 RunSeq
0 ... 32000
p20049 (60)
I0
I1
I2
I3
Q
[0]
OR 2 inputs
p20054
[1]
[2]
[3]
OR 2 output Q
r20055
OR 2 RTG
1 ... 9999
p20056 (9999)
OR 2 RunSeq
0 ... 32000
p20057 (80)
I0
I1
I2
I3
Q
[0]
OR 1 inputs
p20050
[1]
[2]
[3]
OR 1 output Q
r20051
OR 1 RTG
1 ... 9999
p20052 (9999)
OR 1 RunSeq
0 ... 32000
p20053 (70)
I0
I1
I2
I3
Q
[0]
OR 3 inputs
p20058
[1]
[2]
[3]
OR 3 output Q
r20059
OR 3 RTG
1 ... 9999
p20060 (9999)
OR 3 RunSeq
0 ... 32000
p20061 (90)