Function diagrams
Safety Integrated
2-564
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Fig. 2-63 2812 – Basic Functions, F-DI: Fail-safe Digital Input
- 2812 -
Function diagram
87654321
FP_2812_97_63.vsd
Safety Integrated
G120 CU240E-2/E-2 DP
13.12.2010 V4.4
Basic Functions, F-DI: Fail-safe Digital Input
+24V OUT
Kl.9
DI5Kl.17
GND
Kl.28
DI4Kl.16
&
DI COM2
Kl.34
F-DI0
=1
SI STO t_debou P1
0.00 ... 100.00 [ms]
p9651 (1.00)
SI STO t_debou P2
0.00 ... 100000.00 [μs]
p9851 (0.00)
[2810.4]
DI COM
Kl.69
F-DI: Fail-safe Digital Input