EasyManua.ls Logo

Siemens SINAMICS G120 - r0334[0...n] Actual motor-torque constant; Mot kT act; p0335[0...n] Motor cooling type; Motor cooling type; r0337[0...n] Rated motor EMF; Mot EMF_rated

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-61
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the torque constant of the synchronous motor used.
Dependency: IEC drives (p0100 = 0): unit Nm / A
NEMA drives (p0100 = 1): unit lbf ft / A
Note: This parameter is not used for induction motors (p0300 = 1xx).
For synchronous motors, parameter r0334 is calculated from p0305, p0307 and p0311.
Description: Sets the motor cooling system used.
Value: 0: Non-ventilated
1: Forced cooling
2: Liquid cooling
128: No fan
Dependency: For 1LA7 motors (refer to p0300), the parameter is pre-set as a function of p0307 and p0311.
Caution: When selecting a catalog motor (p0301), this parameter is automatically pre-assigned and is write protected. Infor-
mation in p0300 should be carefully observed when removing write protection.
Note: The parameter influences the thermal 3-mass motor model.
1LA7 motors, frame size 56 are operated without fan.
Description: Displays the rated EMF of the motor.
Note: EMF: Electromagnetic force
r0334[0...n] Actual motor-torque constant / Mot kT act
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Data set: MDS
Units group: 28_1 Unit selection: p0100
Min Max Factory setting
- [Nm/A] - [Nm/A] - [Nm/A]
p0335[0...n] Motor cooling type / Motor cooling type
Access level: 2 Calculated: - Data type: Integer16
Can be changed: C(1, 3), T Scaling: - Data set: MDS
Units group: - Unit selection: -
Min Max Factory setting
0 128 0
r0337[0...n] Rated motor EMF / Mot EMF_rated
Access level: 4 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Data set: MDS
Units group: - Unit selection: -
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]