Parameters
List of Parameters
1-370
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Acknowledges the new Safety Integrated password.
Dependency: Refer to: p9762
Note: The new password entered into p9762 must be re-entered in order to acknowledge.
p9762 = p9763 = 0 is automatically set after the new Safety Integrated password has been successfully acknowl-
edged.
Description: Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions inte-
grated in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency: Refer to: p9705
Refer to: C01798
Description: Displays the Safety Integrated version for the drive-integrated safety functions on processor 1.
Index: [0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Note: Example:
r9770[0] = 2, r9770[1] = 60, r9770[2] = 1, r9770[3] = 0 --> Safety version V02.60.01.00
Description: Displays the supported Safety Integrated monitoring functions.
Processor 1 determines this display.
Dependency: Refer to: r9871
Note: STO: Safe Torque Off
p9763 SI password acknowledgement / SI ackn password
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0000 hex FFFF FFFF hex 0000 hex
r9765 SI Motion forced checking procedure remaining time (processor 1) /
SI Mtn dyn rem P1
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- [h] - [h] - [h]
r9770[0...3] SI version drive-integrated safety function (processor 1) / SI version Drv P1
CU240E-2
CU240E-2 DP
CU240E-2 DP F
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r9771 SI common functions (processor 1) / SI general fct P1
CU240E-2 Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 STO supported via terminals Yes No 2804