List of Parameters
Parameters
1-347
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the first index of the signal source being searched for.
The signal source to be searched for is set in p9484 (BICO-coded) and the search result is specified using the num-
ber (r9485) and the first index (r9486).
Dependency: Refer to: p9484, r9485
Note: The signal source to be searched is set in p9484 (BICO-coded).
The search result is contained in r9482 and r9483 and is specified by the count (r9485) and the first index (r9486).
Description: Sets the enable signals for the safe motion monitoring.
Dependency: Refer to: F01682, F01683
Note: For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely-Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
Description: Sets the enable signals for the safe motion monitoring.
Dependency: Refer to: F01682, F01683
Note: For bit 30 = 1, PROFIsafe telegram 900 must be configured in the F host.
A change only becomes effective after a POWER ON.
F-DI: Failsafe Digital Input
SDI: Safe Direction (safe motion direction)
SLS: Safely-Limited Speed
SSM: Safe Speed Monitor (safety-relevant feedback signal from the velocity monitoring)
r9486 BICO interconnections signal source search first index / BICO S_src srchIdx
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p9501 SI Motion enable safety functions (processor 1) / SI Mtn enable P1
PM240
PM250
PM260
CU240E-2 DP F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0000 0000 0000 0000 0000 0000
0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable SLS Enable Inhibit -
16 Enable SSM hysteresis and filtering Enable Inhibit 2860
17 Enable SDI Enable Inhibit 2861
30 Enable F-DI in PROFIsafe telegram 900 Enable Inhibit -
p9501 SI Motion enable safety functions (processor 1) / SI Mtn enable P1
PM240
PM250
PM260
CU240E-2 F
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: C(95) Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0000 0000 0000 0000 0000 0000
0000 0000 bin
Bit field: Bit Signal name 1 signal 0 signal FP
00 Enable SLS Enable Inhibit -
17 Enable SDI Enable Inhibit 2861