Parameters
List of Parameters
1-432
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 / Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Sets the signal source of the switch setting I of instance BSW 0 of the binary changeover switch.
Description: Display parameter for output quantity Q of instance BSW 0 of the binary changeover switch.
Description: Setting parameter for the run-time group in which the instance BSW 0 of the binary changeover switch is to be
called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run sequence of instance BSW 0 within the run-time group set in p20211.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
Description: Sets the signal source of input quantities I0 and I1 of instance BSW 1 of the binary changeover switch.
Index: [0] = Input I0
[1] = Input I1
p20209 BI: BSW 0 switch setting I / BSW 0 sw_setting
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0
r20210 BO: BSW 0 output Q / BSW 0 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p20211 BSW 0 run-time group / BSW 0 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
1 9999 9999
p20212 BSW 0 run sequence / BSW 0 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0 7999 580
p20213[0...1] BI: BSW 1 inputs / BSW 1 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0