List of Parameters
Parameters
1-453
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Sets the signal source for trigger input I, D input D, set input S, and reset input R of instance DFR 2 of the D flipflop.
Index: [0] = Trigger input I
[1] = D input D
[2] = Set S
[3] = Reset R
Description: Display parameter for output Q of instance DFR 2 of the D flipflop.
Description: Display parameter for the inverted output QN of instance DFR 2 of the D flipflop.
Description: Setting parameter for the run-time group in which instance DFR 2 of the D flipflop is to be called.
Value: 1: Run-time group 1
2: Run-time group 2
3: Run-time group 3
4: Run-time group 4
5: Run-time group 5
6: Run-time group 6
9999: Do not calculate
Description: Setting parameter for the run-time group of instance DFR 2 within the run-time group set in p20332.
Note: The function blocks with a lower run sequence value are calculated before function blocks with a higher run
sequence value.
p20329[0...3] BI: DFR 2 inputs / DFR 2 inputs
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - 0
r20330 BO: DFR 2 output Q / DFR 2 output Q
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
r20331 BO: DFR 2 inverted output QN / DFR 2 inv outp QN
Access level: 3 Calculated: - Data type: Unsigned32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- - -
p20332 DFR 2 run-time group / DFR 2 RTG
Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
1 9999 9999
p20333 DFR 2 run sequence / DFR 2 RunSeq
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: T Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
0 32000 870