Siemens SINAMICS G120 - r1732[0...1] CO: Direct-axis voltage setpoint; Direct U set; r1733[0...1] CO: Quadrature-axis voltage setpoint; Quad U set; p1740[0...n] Gain resonance damping for encoderless closed-loop control; Gain res_damp; p1745[0...n] Motor model error threshold stall detection; MotMod ThreshStall

Siemens SINAMICS G120
750 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
List of Parameters
Parameters
1-225
© Siemens AG 2011 All Rights Reserved
SINAMICS G120 Control Units CU240B/E-2 Parameter Manual (LH11), 01/2011
Description: Displays the direct-axis voltage setpoint Ud.
Index: [0] = Unsmoothed
[1] = Smoothed with p0045
Description: Displays the quadrature-axis component of voltage setpoint Uq.
Index: [0] = Unsmoothed
[1] = Smoothed with p0045
Description: Defines the gain of the controller for resonance damping for operation with sensorless vector control in the range
that current is injected.
Description: Sets the fault threshold in order to detect a motor that has stalled.
If the error signal (r1746) exceeds the parameterized error threshold, then status signal r1408.12 is set to 1.
Dependency: If a stalled drive is detected (r1408.12 = 1), fault F07902 is output after the delay time set in p2178.
Refer to: p2178
Note: Monitoring is only effective in the low-speed range (below p1755 * (100% - p1756)).
Description: Signal to initiate stall detection
Note: The signal is not calculated while magnetizing and only in the low speed range (below p1755 * (100 % - p1756)).
r1732[0...1] CO: Direct-axis voltage setpoint / Direct U set
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Data set: -
Units group: 5_1 Unit selection: p0505
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
r1733[0...1] CO: Quadrature-axis voltage setpoint / Quad U set
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2001 Data set: -
Units group: 5_1 Unit selection: p0505
Min Max Factory setting
- [Vrms] - [Vrms] - [Vrms]
p1740[0...n] Gain resonance damping for encoderless closed-loop control / Gain res_damp
Access level: 3 Calculated: p0340 = 1,3,4 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Data set: DDS, p0180
Units group: - Unit selection: -
Min Max Factory setting
0.000 10.000 0.025
p1745[0...n] Motor model error threshold stall detection / MotMod ThreshStall
Access level: 3 Calculated: p0340 = 1,3 Data type: FloatingPoint32
Can be changed: U, T Scaling: - Data set: DDS, p0180
Units group: - Unit selection: -
Min Max Factory setting
0.0 [%] 1000.0 [%] 5.0 [%]
r1746 Motor model error signal stall detection / MotMod sig stall
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Data set: -
Units group: - Unit selection: -
Min Max Factory setting
- [%] - [%] - [%]