Chapter 2 TL1 Reference
Retrieve Phase Data
104 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
There is one line for each data point in the specified time between start and stop
times. Only the number of values currently available are returned.
Example:
SSU_2000 06-05-30 14:50:52
M 100 COMPLD
"S1A04-01:06-05-30,14-48-20,PHA,CLK-A,100,(-23)"
;
Related Commands
Set Phase Zero, on page 166
Set Phase Build-Out Parameter, on page 169