Chapter 3 ICS Command Reference
FREQUENCY
210 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
FREQUENCY
Use this command to display the input frequency data from a selected input port.
Level 0 Not applicable
Level 1
FREQUENCY [xAy][{A|B}]
Use this command to view the frequency measurement from a selected
input module. If you do not provide a parameter, frequency
measurement on the selected clock to all inputs displays.
Options are:
A|B Clock A or Clock B
Level 2 Same as Level 1 operation
Level 3 Same as Level 1 operation
Level 4 Same as Level 1 operation
Remarks None
Related INPUT, PHASE
RestrictionsNone
Example
SSU_2000->FREQUENCY
1A04-01 FreqA:2001-06-18T20:54:19, 0
1A04-02 FreqA:2001-06-18T20:54:19, 1
1A04-03 FreqA:2001-06-18T20:54:19, 1
1A09-01 FreqA:2001-06-18T20:54:19, 3
1A09-02 FreqA:2001-06-18T20:54:19, 2
1A09-03 FreqA:2001-06-18T20:54:19, 1