EasyManuals Logo

Symmetricom SSU-2000 Technical Reference

Symmetricom SSU-2000
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #132 background imageLoading...
Page #132 background image
Chapter 2 TL1 Reference
Set Alarm Cutoff
132 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set Alarm Cutoff
This command activates the Alarm Cutoff (ACO) function. The ACO remains active
until a new alarm is reported, or an existing alarm is elevated. The command
creates a momentary change of state (pulse) on the alarm relay, which allows a
specially-built alarm panel to squelch the audio alarm. Alarm panels that do not
have this capability ignore the pulse. Contact your Symmetricom representative for
further details on this alarm panel.
Syntax
SET-ACO:[tid]::ctag;
Related Commands
Retrieve Alarm Cutoff, on page 36