Chapter 3 ICS Command Reference
KEEPALIVE
220 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
KEEPALIVE
Use this command to enable a “keep-alive” mode that generates a recurring event,
based on a user settable time, to alert the upstream support system that the
SSU-2000 and associated communication path is functional.
Level 0: NA
Level 1:
KEEPALIVE
Displays the “keep-alive” time, the length of time between automatic
events that are generated for upstream support systems.
Level 2: Same as level 1 operation
Level 3: Same as Level 2 operation with the following additions:
KEEPALIVE [TL1|SNMP] [time]
Options are:
TL1 Sets the TL1 session keep-alive time
SNMP Sets the SNMP session keep-alive time
time Value in minutes, minimum is 1 minute, maximum is 60
minutes. If 0 minutes are specified, it means ‘keep-alive’ is
disabled
Level 4: Same as level 3 operation
Remarks None
Related None
RestrictionsThe ICS session in RS232 or telnet is not affected.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals