Chapter 2 TL1 Reference
Retrieve Output PQL
98 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Output PQL
This command returns the current value for the PQL Override function for the specified DS1,
E1, or E1/2048 kHz Output module.
Syntax
RTRV-OUT-PQL:[tid]:[aid]:ctag;
Response Format
^^^"aid:pql" <cr lf>
where:
aid = module access identifier
pql = the Priority Quality Level [0, 1-16]. If the value is 0, the PQL override
function is disabled and the output SSM is provided by the SSU-2000’s PQL.
Note: the PQL Override function is not persistent.
Related Commands
Set Output PQL, on page 165
Parameter Value Description
aid ALL Retrieves the current PQL override level from all modules.
SxAy Retrieves the current PQL override level from the
specified module.