12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 137
Chapter 2 TL1 Reference
Set Clock Parameters
Set Clock Parameters
This command sets the warmup time and tau values for the specified Clock module.
Syntax
SET-PRMTR-CLK:[tid]:[aid]:ctag::[warmup],[mintau],[maxtau];
Empty fields leave parameters unchanged.
Related Commands
Retrieve Clock Parameters, on page 46
Parameter Format Description
aid S1A1 Sets the parameters for the Clock module in slot 1.
S1A12 Sets the parameters for the Clock module in slot 12.
null Sets the parameters for both Clock modules.
warmup Sets the warmup time constant; set to 1200 seconds
mintau Sets the starting time constant for the specified Clock
module.
maxtau Sets the final time constant value for the specified Clock
module
ST2E tau range = [300–10 000]
ST3E tau range = [150–1200]
TypeI tau range = [150–1200]