Chapter 3 ICS Command Reference
IONAME
218 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
IONAME
Use this command to set an alias name for each input or output port.
Level 0 Not applicable
Level 1
IONAME [xAy]
Use this command to display a previously specified name associated
with each I/O port.
Example:
SSU_2000->ioname
2001-05-24T18:28:23Z ID: SSU2000 Name: SSU_2000
1A05-01 GPS Input
Level 2 Same as Level 1 operation
Level 3 Same as Level 2 operation, with the following additions:
IONAME xAy-z[&&z] {CLR|“io_port_name”}
Use this option to set a name associated with each I/O port. No control
characters are allowed. Multiple spaces between words reduce to one
blank character. The port alias can contain up to 20 characters.
CLR
clears the port name associated with the specified module or port.
Level 4 Same as Level 3 operation
Remarks None
Related None
RestrictionsCLR is an operand, and cannot be used as an I/O port name.