Chapter 2 TL1 Reference
Retrieve Frequency Data
64 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Frequency Data
This command returns the current frequency measurements for the specified
input(s) on the DS1, E1, Sine, and GPS Input modules.
Syntax
RTRV-DATA-FREQ:[tid]:[aid]:ctag;
Response Format
^^^"aid:(freqa),(freqb)"<cr lf>
where:
aid = module or port access identifier
freqa = frequency of the port versus clock A
freqb = frequency of the port versus clock B
Example
SSU_2000 06-06-26 13:38:57
M 100 COMPLD
"S1A03-01:(0),(0)"
"S1A03-02:(0),(0)"
"S1A03-03:(0),(0)"
"S1A04-01:(-3),(-31)"
"S1A05-01:(5),(-23)"
"S1A06-01:(0),(0)"
"S1A06-02:(0),(0)"
"S1A06-03:(0),(0)"
;
Related Commands
Parameter Value Description
[aid] ALL Retrieves the current frequency measurements from all
modules that are currently active in the entire shelf.
S1Ay[-z] Retrieves the current frequency measurements from the
specified module [or port].

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals