12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 57
Chapter 2 TL1 Reference
Retrieve E1 LRM Parameters
Retrieve E1 LRM Parameters
This command returns the E1 Line Re-Timing Module settings.
Syntax
RTRV-PRMTR-LRME1:[tid]:[aid]:ctag;
Response Format
^^^"aid:enable,slip,flt" <cr lf>
where:
aid = module or port access identifier
enable = module or port is enabled [ON | OFF]
slip = slip error threshold in any 24 hour period
flt = fault strategy [AIS | SQUELCH]. It defines Side 1 output generation when
the LRU has a loss of signal on side 1 input, loss of all reference sources (PLL
unlock), or if the input signal’s frequency has exceeded the LRU’s ability to retime
data.
Related Commands
Set DS1 LRM Parameters, on page 144
Parameter Value Description
[aid] ALL Retrieves the parameters from all E1 Line Re-Timing
Modules in the shelf.
SxAy[-z]
Retrieves parameters from the specified E1 Re-Timing
Module [or port].
Fault CTA Installed CTA Not Installed
Side 1 LOS Fault Strategy Fault Strategy
PLL Unlock CTA Engaged Fault Strategy
Excessive Frequency Input Fault Strategy Fault Strategy