Chapter 2 TL1 Reference
Retrieve Signal Fault Alarm Parameters
116 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Signal Fault Alarm Parameters
These commands return the erred and cleared second thresholds for the
appropriate signal faults on the specified DS1, E1, or Composite Clock Input
module.
Syntax
RTRV-PRMTR-AIS:tid:[aid]:ctag;
RTRV-PRMTR-BPV:tid:[aid]:ctag;
RTRV-PRMTR-CRC:tid:[aid]:ctag;
RTRV-PRMTR-LOS:tid:[aid]:ctag;
RTRV-PRMTR-OOF:tid:[aid]:ctag;
Response Format
^^^"aid:prmtr,errcnt,clcnt"<cr lf>
where:
aid = module or port access identifier
prmtr = signal fault [LOS | AIS | OOF | BPV | CRC]
errcnt = setting (in s) for the error threshold. This value is the number of
seconds that the error condition must be present before an alarm is declared.
clcnt = setting (in s) for the clear threshold. This value is the number of seconds
that the port must be free of the error condition before the alarm is cleared.
Related Commands
Set Signal Fault Alarm Parameters, on page 172
Parameter Value Description
[aid] SxAy[-z] Retrieves the error and clear threshold data from the
specified module [or port].

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals