EasyManuals Logo

Symmetricom SSU-2000 Technical Reference

Symmetricom SSU-2000
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #240 background imageLoading...
Page #240 background image
Chapter 3 ICS Command Reference
RESET
240 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
RESET
Use this command to reset the Clock module through the Comm Module.
Level 0: NA
Level 1: NA
Level 2: NA
Level 3:
RESET {xAy}
Resets the specified clock module. It must have an operand to indicate
Clock A or Clock B. Any other operand is invalid. This command requires
the whole entry ‘RESET’ be entered to verify that the user really wants to
restart that module. This command requires a confirmation (YES| NO). If
confirmation failed, no action occurs.
Level 4: Same as Level 3 operation
Remarks None
Related RESTART
RestrictionsThis command uses the COMM module PLD’s CLK A/B reset bit to
reset the clock module. The software is required to hold the RESET bit
for at least for 4 seconds and then writes a zero for that RESET bit.