Chapter 8 Default Settings
E1/2048 kHz Output Module Default Settings
358 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
E1/2048 kHz Output Module Default Settings
The
factory default setting and range for all E1/2048 kHz Output module software
parameters are listed in
Table 8-12
.
Composite Clock Output Module Default Settings
The Composite Clock Output module maintains factory default and current user
configuration settings. The configuration settings for the Composite Clock Output
Module are provided in
Table 8-13.
Table 8-12. E1/2048 kHz Output Module Configuration
Configuration Setting Factory Default Range
Signal Type E1 E1 | 2048
Framing Mode CAS CAS | CCS
PQL Override Disabled 0 | 1 – 16, 0 is disabled
Zero suppression On On | Off
SSM On On | Off
CRC On On
SSM Bit Position 8 4 | 5 | 6 | 7 | 8
Port Output (per port) Enabled Enable | Disable
Bypass Enable Enable | Disable
Port Label (per port) Null Up to 20 printable characters; 0 is
string terminator
Alarm Elevation Time 86 400 s 60 to 500 000 s, 0 is disabled
Squelching 0 1 to 16, 0 is disabled
Table 8-13. Composite Clock Output Module Configuration
Configuration Setting Factory Default Range
Port State Enabled Disabled | Enabled
Min Clock Acquire Acquire | Lock
Bypass On On | Off
Fault Action On Off | On | Auto

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals