12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 59
Chapter 2 TL1 Reference
Retrieve E1 LRM BPV Data
Retrieve E1 LRM BPV Data
This command returns the Bipolar Violation data for the specified E1 Line Re-Timing
Module or port.
Syntax
RTRV-DATA-LRME1BPV:[tid]:[aid]:ctag;
Response Format
^^^"aid:reserved,60srate,24hrate,es,ses,sesr" <cr lf>
where:
aid = module or port access identifier
reserved is a reserved field for future use; no value (empty field) is returned
60srate = BPV error rate (floating value) per second in a 60-second window
24hrate = BPV error rate (floating value) per second in an 86400-second
window
es indicates (integer value) that the BPV accumulates BPV Errored Seconds
(BPV-ES) when any seconds have a BPV error
ses indicates (integer value) that the BPV accumulates BPV Severely Errored
Seconds (BPV-SES) when any seconds have a severely BPV error
sesr = BPV Severely Errored Ratio (floating value)
Related Commands
Parameter Value Description
[aid] ALL Retrieves the current BPV data from all E1 Line
Re-Timing Modules that are currently active in the entire
shelf.
SxAy[-z] Retrieves the current BPV data from the specified E1
Line Re-Timing Module [or port].