Chapter 6 Alarms and Events
DS1/E1 Input Module Alarms and Events
308 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
224 IoName, Set A user has set the IO Name.
251
Err Delay, (0), 10 sec, COML
An alarm delay time change.
252 Alm Level, (2), Maj, COML An alarm level change.
253 Elevate Time 86400 sec,
COML
An alarm elevation time change.
254 Setup, Save, COML User defaults have been set and saved.
Table 6-11. DS1/E1 Input Module Alarm Defaults
ID Description Alarm Level
000 LOS Major
001 AIS Major
002 OOF Minor
003 BPV Minor
004 CRC Minor
005 MTIE/L1 Minor
006 MTIE/L2 Major
007 PQL Minor
008 SSM Major
009 Ref Qualifier Minor
010 Clk PLL Major
011 Inp PLL Major
012 Phase Hdw Major
013 FREQ Minor
014 Hdw Config Major
Table 6-10. DS1/E1 Input Module Alarm and Event Messages (Continued)
Alarm/
Event/
Trap ID
Typical Alarm/Event/Trap
Response
Description/
Corrective Action