Chapter 2 TL1 Reference
Set Phase Zero
166 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set Phase Zero
This command sets the input phase to zero for the designated port(s) or all input
ports with an aid of null or ALL. If
clksrc is specified [CLK-A | CLK-B], only the one
phase value is set to zero; otherwise both values are set to zero.
Syntax
SET-PHASE-ZERO:[tid]:[aid]:ctag[::clksrc];
Related Commands
Retrieve Phase Data, on page 103
Parameter Format Description
aid S1Ay[-z] Sets the input phase on the selected Input module or port
to zero
clksrc CLK-A |
CLK-B
Sets the phase value for the specified Clock module to
zero. If not specified, phase values for both Clock
modules are set to zero.