12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 161
Chapter 2 TL1 Reference
Set MTIE Parameters
Set MTIE Parameters
This command sets the input MTIE alarm thresholds (EL1 or EL2) and the clear
thresholds (CL1 or CL2) for the specified input. This command is valid for DS1, E1,
Sine, and GPS Input modules.
Syntax
SET-PRMTR-MTIE:[tid]:[aid]:ctag::[threshold],[t10],[t100],[t1k],
[t10k],[t100k];
Related Commands
Retrieve MTIE Parameters, on page 92
Parameter Format Description
aid S1Ay[-z] Sets the parameters for the specfied Input module [or
port].
threshold EL1 | EL2 Sets the input MTIE alarm threshold for the specified
module [or port].
CL1 | CL2
Sets the clear threshold for the specified module [or port].
t10,
t100,
t1k,
t10k,
t100,
Sets the error limits in ns for the measurement time
period.
Range = [0 – 60000]