Chapter 2 TL1 Reference
Retrieve Clock Parameters
46 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Clock Parameters
This command returns the settings for the Clock module designated by the aid.
Syntax
RTRV-PRMTR-CLK:[tid]:[aid]:ctag;
Response Format
^^^"aid:warmup,mintau,maxtau,clkar,inpswt,inpsel,mintaulimit,maxtau
limit" <cr lf>
where:
aid = Clock module access identifier
warmup = warmup delay time in s
mintau = starting time constant in s
maxtau = final time constant value in s
clkar = current setting for the Clock Auto-Return mode [ON | OFF]
inpswt = input switch {AR|AS|OFF} for Auto-Return (revertive), Auto-Switch (but
not revertive), or no auto switch
inpsel = {PRI|PQL} for priority or sync message (PQL) selection of inputs
mintaulimit = minimum tau limit
maxtaulimit = maximum tau limit
Related Commands
Set Clock Parameters, on page 137
Parameter Value Description
[aid] ALL Retrieves parameters from all Clock modules in the shelf.
S1A1 |
S1A12
Retrieves parameters from the specified Clock module.