Chapter 3 ICS Command Reference
SECURITY
242 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
SECURITY
This command provides the security interface to the SSU-2000. This command
works with the USERS command to allow an Administrator-level user to change
passwords, to query the security log, set the login failed attempts threshold, set the
user lockout timer, and set the password aging timer.
Level 0: NA
Level 1: NA
Level 2: NA
Level 3: NA
Level 4:
SECURITY
SECURITY LOG {count}
SECURITY FAIL {DISABLE|2-5}
SECURITY LOCKOUT {10-86400}
SECURITY AGING {0|{10-360}}
If you do not specify parameters in the command, the current security
settings display.
The options are:
LOG Sets the specified number (count) of the latest security
entries to display. If no count is specified, it displays the
latest one. The count is up to the max resource of the
COMM Module in the NVRAM. If it is too big, the command
automatically adjusts the number to its own maximum.
FAIL Sets the login failed attempt threshold. The range is 2 to 5.
The default is 0 (i.e. User Lockout disabled).
LOCKOUT Sets the user lockout recovery timer (in seconds). This
timer determines how long a user is locked out when the
login failure threshold is reached. The range is from 10 to
86400 seconds. The default is 60 seconds.
AGING Determines how long (in days) a password is valid. The
range is from 10 to 360 days; the default is 0 (aging
disabled).
Remarks None
Related USERS
RestrictionsNone

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals