12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 355
Chapter 8 Default Settings
DS1 and E1 Line Re-timing Module Default Settings
DS1 and E1 Line Re-timing Module Default Settings
Table 8-9 lists settings and factory defaults for the Line Re-timing Modules.
MTIE T10K Clear Limit 1 790 0 to 60 000
MTIE T10K Clear Limit 2 990 0 to 60 000
MTIE T100K Clear Limit 1 1440 0 to 60 000
MTIE T100K Clear Limit 2 1800 0 to 60 000
MTIE Limit 1 Alarm Mode Minor
Ignore | Report | Minor | Major | Critical
MTIE Limit 2 Alarm Mode Major
Ignore | Report | Minor | Major | Critical
Alarm Severity Minor for most alarms
Major for LOS
Ignore | Report | Minor | Major | Critical
Alarm Set Delay 0 seconds 0 to 172 800 seconds
Alarm Elevation Time 86 400 seconds 60 to 500 000 seconds, 0 is disabled
Port Status Disabled Enabled/Disabled
Port Name Any user-selected string from 0–20 chars
Table 8-9. DS1 Line Re-timing Module Configuration
Configuration Setting
Factory
Default
Range
DS1 Line Re-Timing Module
Slips Threshold Error = 4,
Clear <4
1 to 255 (in any 24 hour period)
Fault Strategy AIS AIS
SQUELCH
Port Enable Enabled Enabled
Disabled
Port LBO 1 (0-133 ft) 1 = 0–133 ft
2 = 133–266 ft
3 = 266–399 ft
4 = 399–533 ft
5 = 533–655 ft
Circuit ID None (blank) String from 0-43 characters (only valid TL1 characters
are supported)
Table 8-8. Japanese Sine Wave Input Module Configuration Settings (Continued)
Configuration Setting Factory Default Range