12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 107
Chapter 2 TL1 Reference
Retrieve Reports
Retrieve Reports
This command returns only reports (non-alarm) information from the stored event
data. An aid or aid range may be used to limit the report to specified modules. The
aid code is optional. With an aid of ALL or null, all report data between start and stop
time is returned.
Syntax
RTRV-EVENT-REPORT:[tid]:[aid]:ctag::[count],[start],[stop];
Response Format
One line containing the time stamp and event message is returned for each report in
the log.
^^^"aid:ntfcncde,condtype,srveff,ocrdat,ocrtm:condscr" <cr lf>
where:
aid = module access identifier
ntfcncde = Notification Code (NA)
condtype = Condition Type (event number)
srveff = service affecting flag [SA | NSA]: SA = service affecting, NSA =
non-service affecting
ocrdat occurrence date
ocrtm = occurrence time
condstr = condition description string
Parameter Value Description
[aid] ALL Retrieves all report data between the specified start and
stop time from all modules.
SxAy Retrieves report data between the specified start and stop
time from the specified module.
[count] 1 – 500 Specifies the number of reports to retrieve. The default
count is 1.
[start] MM-DD,
HH:MM
Specifies the start date and time for data. If the date is null
but followed by a time, the command defaults to the current
date. If the start time is null, but preceded by a date, the
command defaults to the current time. If the start date and
time are null, the command defaults to the start of the data.
The comma must be present to indicate a null start time.
[stop] MM-DD,
HH:MM
Specifies the stop date and time for data. If the date is null
but followed by a time, the command defaults to the current
date. If the stop time is null but preceded by a date, the
command defaults to the current time. If the stop date and
time is null, the command defaults to the end of the data.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals