12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 147
Chapter 2 TL1 Reference
Set E1 LRM Parameters
Set E1 LRM Parameters
This command sets the parameters for the specified E1 Line Re-timing Module or
port.
Syntax
SET-PRMTR-LRME1:[tid]:[aid]:ctag::[enable],[slip],[bpv],[flt];
Related Commands
Retrieve E1 LRM Parameters, on page 57
Parameter Format Description
aid S1Ay[-z] Sets the parameters for the specfied E1 LRM module [or
port].
enable ON | OFF Turns the specified module [or port] on or off.
slip 0, 1 - 255 Sets the slip error threshold in any 24 hour period. If the
set to zero, the accumulated slip error counts are
cleared.
bpv CLR | NOP Clears the BPV error count and accumulated error ratio.
NOP is an empty field with no operation.
flt AIS |
SQUELCH
Defines side 1 output generation when the LRU has a
loss of signal on side 1 input, loss of all reference
sources (PLL unlock), or if the input signal’s frequency
has exceeded the LRU’s ability to retime data.
Fault CTA Installed CTA Not Installed
Side 1 LOS FLT STRATEGY FLT STRATEGY
PLL Unlock CTA Engaged FLT STRATEGY
Excessive Input
Frequency
FLT STRATEGY FLT STRATEGY