12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 41
Chapter 2 TL1 Reference
Retrieve Alarm Status
Retrieve Alarm Status
This command returns the current status of alarms from a specified module.
Syntax
RTRV-STATUS-ALARM:[tid]:[aid]:ctag;
Response Format
^^^"aid:almnum,stat" <cr lf>
where:
aid = module or port access identifier
almnum = alarm number for that aid
status = current state of each alarm condition [OK | BAD]
Related Commands
Parameter Value Description
[aid] SxAy Retrieves the Alarm parameters from the specified
module.