12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 289
Chapter 6 Alarms and Events
Message Format
SNMP Trap Message Format
The following event message is an example of the response received from an
autonomous event trap. Table 6-1 provides a description of the response content.
For more information on MIB items, refer to the file SSU.MIB.
Tue Jun 20 08:35:26 2006 SNMPv2c trap from [192.168.21.18]
sysUpTime : (6496500)
snmpTrapOID : ssuEvent(1.3.6.1.4.1.601.3.1.1.52.0.1)
tpTag : (12)
tpEvt : (1)
tpId : (199)
tpMCode : (1013)
tpTimestamp : (0x07:d6:06:14:08:23:1a:00:2b:00:00)
tpChassis : (1)
tpSlot : (6)
tpPort : (1)
tpAlmCode : (5)
tpNtfCode : (5)
tpElevated : (2)
tpDescr : (Port, Enable, TELA)
Table 6-1. SNMP Event Message Format
MIB
Definition
Content Example Content Description
SysUpTime (6496500) System operating time (in seconds)
snmpTrapOID ssuEvent (1.3.6.1.4.1.601.3.1.1.52.0.1) SSU object identifier (includes the system,
modules, ports, variables, etc.)
tpTag (12) Trap counter (number of traps sent)
tpEvt (1) Event Type
1 = autonomous
2 = user requested event to be resent
tpId
(199)
1
Trap Identification
tpMCode (1013) Symmetricom's module code number
tpTimestamp (0x07:d6:06:14:08:23:1a:00:2b:00:00) Event timestamp
tpChassis (1) Shelf ID (1 through 5)
tpSlot (6) Module slot number
tpPort (1) Module port number

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals