EasyManuals Logo

Symmetricom SSU-2000 Technical Reference

Symmetricom SSU-2000
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #290 background imageLoading...
Page #290 background image
Chapter 6 Alarms and Events
Message Format
290 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
tpAlmCode (5) Alarm code
1 = minor
2 = major
3 = critical
4 = ignore
5 = report
tpNtfCode (5) Notification code
1 = minor
2 = major
3 = critical
5 = report
6 = clear
tpElevated (2) Elevated alarm indicator
1 = yes
2 = no
tpDescr
(Port, Enable, TELA)
2
Trap Message
Note:
1
Refer to Module specific Alarm/Event/Trap ID for values.
2
Refer to Module specific Alarm/Event/Trap Response for message content.
Table 6-1. SNMP Event Message Format (Continued)
MIB
Definition
Content Example Content Description