12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 37
Chapter 2 TL1 Reference
Retrieve Alarm Elevation Time
Retrieve Alarm Elevation Time
This command returns the time for alarm elevation, from 60 seconds to 500 000
seconds, for the specified module. A setting of 0 (zero) means the alarm does not
automatically elevate to the next level. When an alarm has been at MINOR or
MAJOR level continuously for
elevtime seconds, then it is elevated to the next
level.
Syntax
RTRV-PRMTR-ELTIME:[tid]:[aid]:ctag;
Response Format
^^^"aid:elevtime" <cr lf>
where:
aid = module access identifier
elevtime = alarm elevation time for the specified module
Related Commands
Set Alarm Level Parameters, on page 134
Parameter Value Description
[aid] SxAy Retrieves the elevtime parameter from the specified
module.