Chapter 2 TL1 Reference
Retrieve MTIE Parameters
92 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve MTIE Parameters
This command returns the MTIE threshold settings for the DS1, E1, Sine, or GPS
Input module or port designated by the aid.
Syntax
RTRV-PRMTR-MTIE:[tid]:[aid]:ctag;
Response Format
There are always four lines returned for each input port, one for each limit.
^^^"aid:MTIE,EL1,t10,t100,t1000,t10000,t100000" <cr lf>
^^^"aid:MTIE,EL2,t10,t100,t1000,t10000,t100000" <cr lf>
^^^"aid:MTIE,CL1,t10,t100,t1000,t10000,t100000" <cr lf>
^^^"aid:MTIE,CL2,t10,t100,t1000,t10000,t100000" <cr lf>
where:
The first line contains the module or port aid and the error threshold settings for EL1.
The second line contains the module or port aid and the error threshold settings for
EL2.
The third line contains the module or port aidand the clear threshold settings for CL1.
The fourth line contains the module or port aid and the clear threshold settings for
CL2.
Example
SSU_2000 06-06-26 15:06:38
M 100 COMPLD
"S1A05-01:MTIE,EL1,260,440,810,880,1600"
"S1A05-01:MTIE,EL2,325,550,1010,1100,2000"
"S1A05-01:MTIE,CL1,230,400,730,790,1440"
"S1A05-01:MTIE,CL2,290,490,910,990,1800"
;
Parameter Value Description
[aid] ALL Retrieves the MTIE parameters from all Input modules in
the shelf.
S1Ay-z Retrieves MTIE parameters from the specified Input port.