Chapter 2 TL1 Reference
Set Password Confirm
168 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Set Password Confirm
This command confirms the previously-entered SET-USER command when used
with the ADD, PWD or TMP mode value. If this command is successful, the
changed password shall be effective; otherwise, the account status is unchanged.
Syntax
SET-PWD-CONFIRM:[tid]::ctag::password;
Related Command
Set User Parameters
, on page 180
Parameter Format Description
password Specifes a password, up to 20 characters long. This must
exactly match the password parameter used in the
SET-USER command.