12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 233
Chapter 3 ICS Command Reference
PBO
PBO
Use this command to gain access to the phase build-out (PBO) in the input module.
Level 0: NA
Level 1:
PBO
Display the PBO current mode from each input
Level 2: Same as Level 2 operation.
Level 3:
PBO [DISABLE|REPORT|EVENT|NONE]
Options are:
DISABLE PBO disabled
REPORT PBO Enabled, the PBO events sent out and displayed, but
not stored in the COMM event buffer
EVENT PBO Enabled, the PBO events sent out and displayed, but
not stored in the COMM event buffer
NONE PBO Enabled, but no PBO events displayed
Level 4: Same as level 3 operation
Remarks None
Related INPUT, PHASE
RestrictionsNone