12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 351
Chapter 8 Default Settings
DS1 and E1 Input Module Default Settings
MTIE Limits for the E1 Input Module
Table 8-5 provides MTIE limits for the E1 Input Module configuration settings and
factory defaults and ranges.
1000 810 1010 730 910
10 000 880 1100 790 990
100 000 1600 2000 1440 1800
Table 8-5. E1 Input Module – MTIE Limits
Time (s)
Set Limit L1
(ns)
Set Limit L2
(ns)
Clear Limit L1
(ns)
Clear Limit L2
(ns)
10 80 100 70 90
100 800 1000 700 900
1000 1600 2000 1400 1800
10 000 1170 2835 2000 2500
100 000 4260 5330 3800 4800
Table 8-4. DS1 Input Module – MTIE Limits (Continued)
Time (s)
Set Limit L1
(ns)
Set Limit L2
(ns)
Clear Limit L1
(ns)
Clear Limit L2
(ns)