Chapter 2 TL1 Reference
Retrieve Alarm Parameters
40 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Alarm Parameters
This command returns the alarm settings for the specified module, or ALL alarms if
no aid is specified.
Syntax
RTRV-PRMTR-ALARM:[tid]:[aid]:ctag;
Response Format
^^^"aid:almnum,level,startdelay,cleardelay"<cr lf>
where:
aid = module or port access identifier
almnum = alarm number
level = Ignore, Report, Minor, Major, or Critical: [IGN|RPT|MIN|MAJ|CRT]
startdelay = delay time or errored seconds count for start of the alarm
cleardelay = cleared seconds count for clearing of the alarm. Delay numbers
are reported only if they are settable for the alarm; otherwise they are reported as
IMMED (immediate).
Related Commands
Retrieve All Alarms, on page 42
Parameter Value Description
[aid] ALL Retrieves all the alarm parameters from the shelf.
SxAy[-z] Retrieves alarm parameters from the specified module [or
port].