12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 151
Chapter 2 TL1 Reference
Set Input Reference
Set Input Reference
This command sets the current input reference to the designated input port. If the
input port is not a valid reference, then the DENY response is returned. This
command also sets the reference selection mode. For more information on
reference switching, see “Setting the Reference Switching Mode” in the SSU-2000
User’s Guide.
Syntax
SET-INPUT-REF:[tid]::ctag::port[,swtmode][,selmode];
Related Commands
Retrieve Input Data, on page 72
Parameter Value Description
port S1Ay-z Selects the port as the target of the command
[swtmode] AR Sets the Autoreturn (revertive) mode
AS Sets the Autoswitch (non-revertive) mode
OFF Selects no automatic switching on an input fault
[selmode] PRI The Priority level of the input signal is the primary
factor in determining which input is selected
PQL The PQL of the input signal is the primary factor in
determining which input is selected