12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 143
Chapter 2 TL1 Reference
Set DS1/E1 Output Parameters
Set DS1/E1 Output Parameters
This command sets the output port parameters for the specified DS1 or E1 Output
module or port.
Syntax
SET-PRMTR-OUTPUT:[tid]:[aid]:ctag::[pstate],[mode],[level],[bypass],
[zs],[crc],[len],[bit];
Empty fields leave parameters unchanged.
Related Commands
Retrieve DS1/E1 Output Parameters, on page 52
Parameter Format Description
aid SxAy[-z] Sets the parameters for the specfied DS1 or E1 Output
module [or port].
pstate ON | OFF Enables or disable the specified module [or port].
mode ESF | D4 |
CCS | CAS
Sets the output mode of the specified module [or port].
level ACQ | LOCK Outputs are turned on when the active Clock module is at
or above the specified state.
bypass ON | OFF Allows operation when Clock C is the active clock.
zs ON | OFF Turns zero suppression On or Off for the specified
module [or port].
crc ON | OFF Enables or disables error checking.
len 133 | 266
399 | 533
655
Sets the line build-out in feet for DS1 outputs.
bit 4 - 8 Sets the bit number of the Time Slot 0 word used for the
E1 SSM.

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals