EasyManuals Logo

Symmetricom SSU-2000 Technical Reference

Symmetricom SSU-2000
400 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 71
Chapter 2 TL1 Reference
Retrieve Header
Retrieve Header
This command allows you to verify that the SSU-2000 is connected to the computer
or network. It may also be used to retrieve the unit name (sid) and date and time.
The only action taken by the SSU-2000 is to respond with the complied message.
Syntax
RTRV-HDR:[tid]::ctag;
Example
SSU_2000 06-05-30 14:56:57
M 100 COMPLD
;
Related Commands
Retrieve Name, on page 93
Retrieve Network Element Type, on page 94

Table of Contents