12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 149
Chapter 2 TL1 Reference
Set GPS Input Parameters
Set GPS Input Parameters
This command sets the parameters for the GPS Input module.
Syntax
SET-PRMTR-GPS:[tid]:[aid]:ctag::[pri],[pql],[sigma];
Related Commands
Retrieve GPS Data, on page 67
Retrieve GPS Available Data, on page 66
Retrieve GPS Input Parameters, on page 69
Retrieve GPS Position, on page 70
Parameter Format Description
aid
S1A3 | S1A5
Sets the parameters for the specified GPS Input module.
pri 0 | 1 - 10 Sets the Priority for the specified module; 0 = Monitor.
pql 1 - 16 Sets the Priority Quality Level for the specified module.
sigma 10 - 1000 Sets the limit of the noise measurement, in μs.