Chapter 3 ICS Command Reference
TIME
252 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
TIME
Use this command to access the timekeeping facilities.
Level 0 Not applicable
Level 1
TIME
Use this command to view the current time within the unit. The time is
displayed in the following format:
SSU_2000->time
T18:29:41Z
Level 2 Same as Level 1 operation
Level 3
TIME [T]hh:mm:ss
TIME OFFSET [+/-]hh:mm
If no parameter is given, then the current local time with the local time
offset is displayed.
Options are:
hh:mm:ss Set the current local time for the unit. If the time is set by a
receiver such as GPS, then the time is locked and cannot
be changed.
OFFSET Sets the local time offset, which is the difference between
local and UTC time. If local time is ahead of UTC, then
offset is positive; If local time is behind UTC, then offset is
negative.
Use this command to set the current time within the unit.
Level 4 Same as Level 3 operation
Remarks None
Related DATE
RestrictionsNone

Table of Contents

Other manuals for Symmetricom SSU-2000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Symmetricom SSU-2000 and is the answer not in the manual?

Symmetricom SSU-2000 Specifications

General IconGeneral
BrandSymmetricom
ModelSSU-2000
CategoryPower Supply
LanguageEnglish

Related product manuals