12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 251
Chapter 3 ICS Command Reference
TDEV
Example
SSU_2000->tdev 1a9-1
TDEV for 1A09-01, on Clock A:
Start Time: 2001-06-19T01:00:00
Stop Time: 2001-06-19T13:57:00
The TDEV ( 0.10 sec) is 0.56
The TDEV ( 0.30 sec) is 0.33
The TDEV ( 0.60 sec) is 0.24
The TDEV ( 1.00 sec) is 0.18
The TDEV ( 3.00 sec) is 0.11
The TDEV ( 6.00 sec) is 0.09
The TDEV ( 10.00 sec) is 0.07
The TDEV ( 30.00 sec) is 0.06
The TDEV ( 60.00 sec) is 0.07
The TDEV ( 100.00 sec) is 0.09
The TDEV ( 300.00 sec) is 0.14
The TDEV ( 600.00 sec) is 0.19
The TDEV ( 1000.00 sec) is 0.24
The TDEV ( 3000.00 sec) is 0.62
The TDEV ( 6000.00 sec) is 1.22
The TDEV (10000.00 sec) is 1.60