Chapter 2 TL1 Reference
Retrieve Japan Sine Input Parameters
78 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
Retrieve Japan Sine Input Parameters
This command returns the settings for the Japan Sine Input module or port
designated by the aid.
Syntax
RTRV-PRMTR-INPSINE:[tid]:[aid]:ctag;
Response Format
^^^"aid:pstate,pri,pql,frequency,csflt" <cr lf>
where:
aid = module or port access identifier
pstate = port enabled state [ON | OFF]
pri = priority 1 (highest) through 10 (lowest) or MON for monitor
pql = provisioned priority quality level [1 – 16]
frequency = clock frequency in MHz [1.544 | 6.312]
csflt = Cesium falut status [HI | LO | OFF | NA]
Related Commands
Set Japan Sine Input Parameters, on page 153
Parameter Value Description
[aid] ALL Retrieves the parameters from all Japan Sine Input
modules in the shelf.
S1Ay[-z] Retrieves parameters from the specified Japan Sine Input
module [or port].