Chapter 3 ICS Command Reference
OUTPUT
230 SSU-2000 Technical Reference 12713020-003-2 Revision F.01 – January 2007
OUTPUT
Use this command to view or set the status of Output modules.
Level 0 Not applicable
Level 1
OUTPUT [xAy]
If you do not provide a parameter, the status information for all output
modules in the unit displays. If you provide an output address, the status
and setup information for the specified output module displays.
Status Information: Output module status, selected clock, status for all
four clocks, redundant partner, output PQL value, and output port status
Setup Information: Framer type, zero suppression (On | Off), minimum
clock level, PLL mask (On | Off)
The alarm level is handled by the ALARM command. The alarm
elevation time is handled by ELEVTIME command.
Example
SSU_2000->output
2001-05-24T18:29:00Z ID: SSU2000 Name: SSU_2000
OUT STA Clk Clk Stat Port Status 1 1 1 1 1 1 1 1 1 1 2
Loc# Sta Sel A B C D Rednt M/S Pql 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0
---- --- --- -------- ----- --- --- --------------------------------------
2A01 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A02 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A03 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A04 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A05 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
2A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A08 Ok A /Y/Y/Y/Y None 2 / / / / / / / / / / / / / / / / / / / /
3A11 Ok A /Y/Y/Y/Y 3A12 (S) 2 / / / / / / / / / / / / / / / / / / / /
3A12 Ok A /Y/Y/Y/Y 3A11 (M) 2 / / / / / / / / / / / / / / / / / / / /
1A06 Ok A /Y/Y/Y/N 1A07 (M) NA / / / / / / / / / / / / / / / / / / / /
1A07 Ok A /Y/Y/Y/N 1A06 (S) NA / / / / / / / / / / / / / / / / / / / /
Level 2 Same as Level 1 operation
Level 3 Same as Level 2 operation, with the following additions:
OUTPUT xAy {ESF|D4|CCS|CAS}
OUTPUT xAy-z[&&z] {E1|2048}
OUTPUT xAy-z[&&z] {ENABLE|DISABLE}
OUTPUT xAy LEVEL {ACQ|LOCK}
OUTPUT xAy BYPASS {ON|OFF}
OUTPUT xAy-z[&&z] {133FT|266FT|399FT|533FT|655FT}
OUTPUT xAy {CRC|ZS} {ON|OFF}
OUTPUT xAy SSM {ON|OFF}
OUTPUT xAy SSM {4|5|6|7|8}
OUTPUT xAy-z[&&z] DUTYCYCLE {63/37|50/50}
OUTPUT xAy-z[&&z] COMPENSATE {275ft|550ft|825ft|1100ft|1375ft|
1650ft|1925ft|2200ft}