12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 81
Chapter 2 TL1 Reference
Retrieve JCC Input Parameters
Retrieve JCC Input Parameters
This command returns the settings for the Japan Composite Clock Input module or
port designated by the aid.
Syntax
RTRV-PRMTR-INPJCC:[tid]:[aid]:ctag;
Response Format
^^^"aid:pstate,pri,pql,400hz" <cr lf>
where:
aid = module or port access identifier
pstate = port enabled state [ON | OFF]
pri = priority 1 (highest) through 10 (lowest) or MON for monitor
pql = provisioned priority quality level [1 – 16]
400hz = 400 Hz sync provision [ON | OFF]
Related Commands
Set JCC Input Parameters, on page 155
Parameter Value Description
[aid] ALL Retrieves the parameters from all JCC Input modules in
the shelf.
S1Ay[-z] Retrieves parameters from the specified JCC Input
module [or port].