12713020-003-2 Revision F.01 – January 2007 SSU-2000 Technical Reference 139
Chapter 2 TL1 Reference
Set Clock Mode
Set Clock Mode
This command sets the clock loop mode to Acquire, Lock, or Hold.
Syntax
SET-CLK-MODE:[tid]:[aid]:ctag::mode;
If you do not specify an aid, then the mode of both Clock modules changes.
Related Commands
Retrieve Clock Status, on page 47
Parameter Value Description
aid S1A1
S1A12
Selects the Clock module as the target for the command.
[mode] ACQ Sets the specified Clock module to the Acquire mode.
LOCK Sets the specified Clock module to the Lock mode.
HOLD Sets the specified Clock module to the Holdover mode.